Sierra Monitor Corporation Switch D F79W User Manual

D-#S-TFI87GB-A  
2. INSTALLATION AND OPERATING ENVIRONMENT  
Design and selection  
3.Model Indication Method  
D
-
Avoid incorrect wiring  
If connections are reversed (power supply line + and power supply line –) on a  
Switch No.  
3-wire type switch, the switch will be protected by a protection circuit. However,  
if the power supply line (+) is connected to the blue wire and the power supply  
line (–) is connected to the black wire, the switch will be damaged.  
Installation & Maintenance Manual  
Auto Switch (Solid State)  
Confirm the specifications.  
Output  
3wire NPN output  
3wire PNP output  
2wire  
Lead wire length  
F79  
F7P  
J79  
No number  
0.5m  
3m  
5m  
Read the specifications carefully and use this product appropriately. The  
product may be damaged or malfunction if it is used outside the range of  
specifications for load current, voltage, temperature or impact.  
L
Z
Operating environment  
Series D-F79(W) / D-F7P(W)  
Indication LED  
Do not use in an area where a magnetic field is generated.  
Auto switches can malfunction or magnets inside actuators can become  
demagnetized.  
Do not use in an environment where the auto switch will be  
continually exposed to water.  
Although switches satisfy IEC standard IP67 construction (JIS C 0920:  
watertight construction), avoid using switches in applications with continual  
exposure to water splash or spray. Poor insulation or swelling of the potting  
resin inside switches may cause malfunction.  
Do not use in an environment with oil or chemicals.  
Consult SMC if auto switches are to be used in an environment with coolant,  
cleaning solvent, various oils or chemicals. If auto switches are used under  
these conditions for even a short time, they may be adversely affected by  
improper insulation, malfunction due to swelling of the potting resin, or  
hardening of the lead wires.  
Do not use in an environment with temperature cycles.  
Consult SMC if switches are used where there are temperature cycles  
other than normal air temperature changes, as there may be adverse  
effects inside the switches.  
Do not use in an area where surges are generated.  
When there are units (solenoid type lifter, high frequency induction furnace,  
motor, etc.) which generate a large amount of surge in the area around  
actuators with solid state auto switches, this may cause deterioration or  
damage to the switches. Avoid sources of surge generation and crossed  
lines.  
Avoid accumulation of iron waste or close contact with magnetic  
substances.  
When a large amount of iron waste such as machining chips or spatter has  
accumulated, or a magnetic substance (something attracted by a magnet) is  
brought into close proximity with an auto switch actuator, it may cause auto  
switches to malfunction due to a loss of the magnetic force inside the  
actuator.  
Take precautions when multiple actuators are used close together.  
When multiple auto switch actuators are used in close proximity,  
magnetic field interference may cause the switches to malfunction.  
Maintain a minimum actuator separation of 40mm.  
Pay attention to the length of time that a switch is ON at an  
intermediate stroke position.  
When an auto switch is placed at an intermediate position of the stroke and  
a load is driven at the time the piston passes, the auto switch will operate,  
but if the speed is too great the operating time will be shortened and the  
load may not operate properly. The maximum detectable piston speed is:  
No number  
1 color display  
D-J79(W) / D-F7BAL  
W
2 color display  
D
-
PC  
Read this manual before using this product.  
For future reference, please keep this manual in a safe place.  
This manual should be read in conjunction with the current catalogue.  
Switch No.  
Output  
3wire NPN output  
Pre-wired connector  
F79  
1.1 General recommendation  
These safety instructions are intended to prevent a hazardous  
situation and/or equipment damage.  
These instructions indicate the level of potential hazard by label of  
"Caution", "Warning" or "Danger".  
To ensure safety of personnel and equipment the safety instructions in  
this manual and the product catalogue must be observed, along with  
other relevant safety practices.  
F7P  
J79  
3wire PNP output  
2wire  
Indication LED  
Connector pin assignment  
Autoswitch operating range [mm]  
No number  
W
1 color display  
A
B
D
M8-3pin connector  
M8-4pin connector  
M12-4pin connector  
2 color display  
Load operating time [ms]  
Lead wire length  
Keep wiring as short as possible  
Although longer wiring does not affect the function, please keep it to  
100m or shorter.  
S
M
0.5m  
1m  
Do not use a load that generates surge voltage.  
D-F7BA  
Switch No.  
Although a zener diode for surge protection is connected at the output side of  
a solid state auto switch, damage may still occur if the surge is applied  
repeatedly. When a load such as a relay or solenoid which generates surge is  
directly driven, use a type of switch with a built-in surge absorbing element.  
Operator error could result in injury or  
equipment damage.  
Caution  
Lead wire length  
L
Z
3m  
5m  
Operator error could result in serious injury  
or loss of life.  
Warning  
Cautions for use in an interlock circuit  
When an auto switch is used for an interlock signal requiring high reliability,  
devise a double interlock system to avoid trouble by providing a mechanical  
protection function, or by also using another switch (sensor) together with  
the auto switch.  
D-F7BA  
PC  
In extreme conditions, there is a possible  
result of serious injury or loss of life.  
Danger  
Switch No.  
Also perform periodic maintenance and confirm proper operation.  
Lead wire length  
Pre-wired connector  
S
M
0.5m  
1m  
Ensure sufficient clearance for maintenance activities.  
When designing an application, be sure to allow sufficient clearance for  
maintenance and inspections.  
Connector pin assignment  
A
B
D
M8-3pin connector  
M8-4pin connector  
M12-4pin connector  
1.1.1. The compatibility of pneumatic equipment is the responsibility  
of the person who designs the pneumatic system or decides  
its specifications.  
Since the products specified here are used in various operating  
conditions,their compatibility for the specific pneumatic system  
must be based on specifications or after analysis and/or tests to  
meet your specific requirements.  
Maintenance  
4.INTENDED CONDITIONS OF USE  
Mount / adjustment  
Do not drop or bump.  
Perform the following maintenance periodically in order to prevent  
possible danger due to unexpected auto switch malfunction.  
1) Securely tighten switch mounting screws.  
If screws become loose or the mounting position is dislocated,  
retighten them after readjusting the mounting position.  
2) Confirm that there is no damage to lead wires.  
Switch model number  
Wiring  
D-F79(W)  
D-F7P(W)  
D-J79(W)  
2 wire  
D-F7BA  
2
Do not drop, bump or apply excessive impacts (1000m/s or more for solid  
1.1.2. Only trained personnel should operate pneumatically operated  
machinery and equipment.  
state switches) while handling. Although the body of the switch may not be  
damaged, the inside of the switch could be damaged and cause a malfunction.  
Do not carry a actuator by the auto switch lead wires.  
Never carry an actuator by its lead wires. This may not only cause broken  
lead wires, but it may cause internal elements of the switch to be damaged  
by the stress.  
Mount switches using the proper tightening torque.  
If a switch is tightened beyond the range of tightening torque, the mounting  
screws, mounting brackets or switch may be damaged.  
On the other hand, tightening below the range of tightening torque may  
allow the switch to slip out of position.  
Mount a switch at the center of the operating range.  
Adjust the mounting position of an auto switch so that the piston stops at  
the center of the operating range (the range in which a switch is ON).  
(The mounting position shown in the catalog indicates the optimum  
position at stroke end.) If mounted at the end of the operating range  
(around the borderline of ON and OFF), operation may be unstable.  
3 wire  
Output  
NPN  
PNP  
Compressed air can be dangerous if an operator is unfamiliar with it  
Assembly, handling or repair of pneumatic systems should be  
performed by trained and experienced operators.  
Application  
IC circuit/Relay/PLC  
5/12/24V DC (4.5 to 28V DC)  
10mA or less  
24V DC Relay/PLC  
To prevent faulty insulation, replace switches or repair lead wires,  
etc., if damage is discovered.  
Power voltage  
Current consumption  
Load voltage  
Load current  
1.1.3. Do not service machinery/equipment or attempt to remove  
component until safety is confirmed.  
Others  
For durability against water, elasticity, application at welding  
site, please consult us.  
1) Inspection and maintenance of machinery/equipment should only be  
performed after confirmation of safe locked-out control positions.  
2) When equipment is to be removed, confirm the safety process as  
mentioned above. Switch off air and electrical supplies and exhaust all  
residual compressed air in the system.  
3) Before machinery/equipment is re-started, ensure all safety measures to  
prevent sudden movement of actuators etc. (Supply air into the system  
gradually to create backpressure, i.e. incorporate a soft-start valve).  
28V DC or less  
24V DC(10 to 28V DC)  
5 to 40mA  
If ON and OFF position (hysteresis) cause problems, please  
40mA or less 80mA or less  
1.5V or less  
consult us.  
(0.8V or less  
0.8V or less  
at 10mA  
Internal voltage drop  
4V or less  
ON position  
Piston moving  
load current)  
direction  
Current leakage  
Operating time  
100 A or less at 24V DC 0.8mA or less at 24V DC  
1ms or less  
Hysteresis  
1.1.4. Contact SMC if the product is to be used in any of the following  
conditions:  
Piston moving  
direction  
Operating range  
Red LED / Most  
Sensitive range  
Green LED  
ON: Red light emitting diode  
Wiring  
Indication light  
D-**W  
1) Conditions and environments beyond the given specifications, or if  
product is used outdoors.  
OFF position  
Operating range Red LED / Most Sensitive range Green LED  
Avoid repeatedly bending or stretching lead wires.  
Broken lead wires can result from wiring patterns which repeatedly apply  
bending stress or stretching force to the lead wires.  
2
2) Installations in conjunction with atomic energy, railway, air navigation,  
vehicles, medical equipment, food and beverage, recreation equipment,  
emergency stop circuits, press applications, or safety equipment.  
3) Equipment intended for use in potentially explosive atmospheres.  
Applications which have the possibility of having negative effects on  
people, property or animals.  
Impact resistance  
Insulation resistance  
Withstand voltage  
Ambient temperature  
Protection structure  
1000m/s  
50M or more at 500V DC mega  
1000V AC for 1 minute (lead wire, between cases)  
-10 to 60  
Confirm proper insulation of wiring.  
Be certain that there is no faulty wiring insulation (contact with other  
circuits, ground fault, improper insulation between terminals, etc.)  
Damage may occur due to excess current flow into a switch.  
Special safety analysis is required.  
Do not wire with power lines or high voltage lines.  
IEC60529 standard IP67  
Wire separately from power lines or high voltage lines, avoiding parallel wiring  
or wiring in the same conduit with these lines. Control circuits containing auto  
switches may malfunction due to noise from these other lines.  
Do not allow short circuit of loads.  
All models of PNP output type switches do not have built-in short circuit  
protection circuits.  
Note that if a load is short circuited, the switch will be instantly damaged  
because of excess current flow into the switch.  
*Take special care to avoid reverse wiring of the brown power supply line  
and the black output line on 3-wire type switches.  
 

Sennheiser Microphone E608 User Manual
Sennheiser Satellite Radio SK 2012 9 User Manual
Shure TV Antenna WA405 User Manual
Snapper Lawn Mower 12RTG Series User Manual
Sony Camera Accessories LCM FD88 User Manual
Sony Car Stereo System CDX 1150 User Manual
Sony Printer UP 970AD User Manual
Spalding Fitness Equipment M415221 User Manual
Stiga Lawn Mower 11 1181 24 User Manual
SV Sound Speaker PB10 NSD User Manual