C O M M E R C I A L
SANDBLASTER
Commercial Electric Water Heaters
With Automatic Self-Cleaning
™
State’s Sandblaster® is the original Self-Cleaning commercial electric water heater, with a proven
Design
design that automatically reduces sediment build-up,the number one threat to any water heater’s life
expectancy and energy efficiency.
Sandblaster electric water heaters are equipped with a cold water inlet tube that
directs incoming cold water to create Self-Cleaning turbulence in the tank.
Self-Cleaning action keeps sediment in suspension, so it does not get a chance to
settle down, and is harmlessly carried out when hot water is drawn.With reduced
sediment build-up,Sandblaster retains its rated efficiency longer,lasts longer,
and helps keep water heating costs down!
Other Sandblaster commercial electric water heater features include:
• Glass-Lined Tank – Three sizes: 50, 80 and 119-gallon capacity.Tank interior is coated with glass
specially developed for water heater use. Tanks rated at 150 psi (1034 kPa) working pressure.
Foam insulation reduces costly heat loss and is vermin proof.
• Elements – Incoloy sheathing for longer life. Low watt density means lower surface temperature
to minimize scale build-up and more surface to heat water. Element sizes from 3 to 6 kW. Use 3,
6 or 9 elements standard; total of 9 to 54 kW input (see chart on page 3).
• Fusing – Protects all elements, thermostats, and internal wiring circuits against excess current
flow. Meets National Electric Code requirements that non-ASME tanks must have internal fusing
when current draw exceeds 48 amps.
• Standard Voltages – 208, 240 and 480V single-phase and three-phase delta. Convertible from
three-phase to single-phase (in field) and vice versa. 277V single-phase also available.
• Terminal Block – Factory installed. Just bring the service to the heater and connect to block.
• Controls – Available with either immersion (IFE models) or surface thermostat (SFE models).
Immersion temperature control adjustable through a range of 60°F to 180°F. Manual reset high
temperature cutoff. Surface mount models have one temperature control (adjustable through a
range of 120°F to 180°F) and manual reset high temperature cutoff per element.Thermostat step
control may be achieved by varying settings on individual temperature controls.All controls located
behind hinged control compartment door for quick, easy access.
The Superior Sandblaster Warranty
Every Sandblaster is covered by a 3-year standard warranty against tank leaks. An optional 5-year extended tank warranty is also available on 50, 80 and
119-gallon models. Unlike other manufacturers, State has so much confidence in Sandblaster’s superior construction and Self-Cleaning design, there is no“fine print”
excluding failure caused by sediment build-up in either the standard 3-year or optional 5-year extended warranty.
For more information on the Sandblaster® contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
SCESS00308
C O M M E R C I A L
SANDBLASTER
Commercial Electric Water Heaters
Maximum Delivery-Constant Use
MAXIMUM DELIVERY IN GALLONS, NOT INCLUDING USEABLE STORAGE
Maximum Delivery (GPH / GPM) at Specified Temperature Rise
Model Size
kW Input
40°
50°
60°
70°
80°
90°
100°
110°
120°
130°
140°
52, 82 or 120-6
52, 82 or 120-9
52, 82 or 120-12
52, 82 or 120-13.5
52, 82 or 120-15
52, 82 or 120-18
52, 82 or 120-24
52, 82 or 120-27
52, 82 or 120-30
52, 82 or 120-36
52, 82 or 120-40.5
52, 82 or 120-45
52, 82 or 120-54
6
9
62 / 1.0
92 / 1.5
49 / 0.82 41 / 0.68 35 / 0.59 31 / 0.51 27 / 0.46 25 / 0.41
74 / 1.23 61 / 1.03 53 / 0.88 46 / 0.77 41 / 0.68 37 / 0.62
22 / 0.4
34 / 0.6
45 / 0.7
50 / 0.8
56 / 0.9
67 / 1.1
90 / 1.5
21 / 0.34 19 / 0.32 18 / 0.29
31 / 0.51 28 / 0.47 26 / 0.44
41 / 0.68 38 / 0.63 35 / 0.59
46 / 0.77 43 / 0.71 40 / 0.66
51 / 0.85 47 / 0.79 44 / 0.73
62 / 1.03 57 / 0.95 53 / 0.88
82 / 1.37 76 / 1.27 70 / 1.17
12
13.5
15
18
24
27
30
36
40.5
45
54
123 / 2.1 98 / 1.64 82 / 1.37 70 / 1.17 61 / 1.03 55 / 0.91 49 / 0.82
138 / 2.3 111 / 1.85 92 / 1.54 79 / 1.32 69 / 1.15 62 / 1.03 55 / 0.92
154 / 2.6 123 / 2.05 103 / 1.71 88 / 1.46 77 / 1.28 68 / 1.14 62 / 1.03
185 / 3.1 148 / 2.46 123 / 2.05 105 / 1.76 92 / 1.54 82 / 1.37 74 / 1.23
246 / 4.1 197 / 3.28 164 / 2.73 140 / 2.33 123 / 2.05 109 / 1.82 98 / 1.63
277 / 4.6 221 / 3.69 185 / 3.08 158 / 2.64 138 / 2.31 123 / 2.05 111 / 1.85 101 / 1.7 93 / 1.54 85 / 1.42 79 / 1.32
308 / 5.1 246 / 4.10 205 / 3.42 176 / 2.93 154 / 2.56 137 / 2.28 123 / 2.05 112 / 1.9 103 / 1.71 95 / 1.58 88 / 1.46
369 / 6.2 295 / 4.92 246 / 4.10 211 / 3.51 185 / 3.08 164 / 2.73 148 / 2.46 134 / 2.2 123 / 2.05 114 / 1.89 105 / 1.76
418 / 6.97 332 / 5.53 277 / 4.62 237 / 3.95 208 / 3.47 185 / 3.08 166 / 2.77 151 / 2.52 138 / 2.3 128 / 2.13 119 / 1.98
461 / 7.7 369 / 6.15 308 / 5.13 264 / 4.39 231 / 3.84 205 / 3.42 185 / 3.08 168 / 2.8 154 / 2.56 142 / 2.37 132 / 2.20
554 / 9.2 443 / 7.38 369 / 6.15 316 / 5.27 277 / 4.61 246 / 4.10 221 / 3.69 201 / 3.4 185 / 3.08 170 / 2.84 158 / 2.64
Electrical Usage Information
Model Numbers
82
Full Load Current in Amperes
Single Phase
Three Phase
240V
Number of
Elements
52
120
kW Input
Wattage
208V
240V
277V
480V
208V
480V
CSB 52 6
CSB 52 9
CSB 82 6
CSB 82 9
CSB 120 6
CSB 120 9
6
9
3
3
3
3
3
3*
6
6
6
2000
3000
4000
4500
5000
6000
4000
4500
5000
6000
4500
5000
6000
28.8
43.3
57.7
64.9
72.1
25.0
37.5
50.0
56.3
62.5
21.7
32.5
43.3
48.7
54.2
65.0
86.6
97.5
108.3
130.0
146.2
162.5
194.9
12.5
18.8
25.0
28.1
31.3
37.5
50.0
56.3
62.5
75.0
84.4
93.8
112.5
16.7
25.0
33.3
37.5
41.6
50.0
66.6
74.9
83.3
99.9
112.4
124.9
149.9
14.4
21.7
28.9
32.5
36.1
43.3
57.7
65.0
72.2
86.6
97.4
108.3
129.9
7.2
10.8
14.4
16.2
18.0
21.7
28.9
32.5
36.1
43.3
48.7
54.1
65.0
CSB 52 12
CSB 52 135
CSB 52 15
CSB 52 18
CSB 52 24
CSB 52 27
CSB 52 30
CSB 52 36
CSB 52 405
CSB 52 45
CSB 52 54
CSB 82 12
CSB 82 135
CSB 82 15
CSB 82 18
CSB 82 24
CSB 82 27
CSB 82 30
CSB 82 36
CSB 82 405
CSB 82 45
CSB 82 54
CSB 120 12
CSB 120 135
CSB 120 15
CSB 120 18
CSB 120 24
CSB 120 27
CSB 120 30
CSB 120 36
CSB 120 405
CSB 120 45
CSB 120 54
12
13.5
15
18
24
27
30
36
40.5
45
54
86.5
75.0
115.4
129.8
144.2
173.1
194.7
216.3
N/A
100.0
112.5
125.0
150.0
168.8
187.5
225.0
6*
9
9
9
*208 volt model may contain three (3) additional elements.
For more information on the Sandblaster® contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
SCESS00308
C O M M E R C I A L
SANDBLASTER
Commercial Electric Water Heaters
Reading Sandblaster Electric Water Heater Model Numbers
C S B
5 2
1 8
S
F
E
CAPACITY
kW INPUT
THERMOST AT
TYPE
ADDERS
MODEL NAME
52 = 50 gallons
82 = 80 gallons
120 = 119 gallons
6 = 6 kW
9 = 9 kW
12 = 12 kW
135 = 13.5 kW
15 = 15 kW
A = ASME Construction
B = 480 Volt
CSA = Canadian Construction
NC = North Carolina Requirements
X = 208 Volt
CSB = Commercial Sandblaster
S = Surface
I = Immersion
18 = 18 kW
24 = 24 kW
27 = 27 kW
30 = 30 kW
36 = 36 kW
405 = 40.5 kW
45 = 45 kW
54 = 54 kW
Y = 277 Volt (only single-phase)
FUSED
WARRANTY
All Models Fused
E = 3 Years
SPECIAL NOTE:
All model numbers appearing on rating plate and carton labels will be compressed.
EXAMPLES: CSB5254IFE; CSB8254IFE; CSB12054IFE.
Sandblaster Electric Sample Specifications
The heater(s) shall be Sandblaster Commercial Electric Model Number
at kW, volts, phase, 60 cycle AC, and listed by Underwriter’s Laboratories. Tank(s) shall be
as manufactured by State Water Heaters or an approved equal. Heater(s) shall be rated
gallon capacity. Heater(s) shall
have 150 psi working pressure and be equipped with extruded high density anode. All internal surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline
borosilicate composition that has been fused-to-steel by firing at a temperature range of 1400°F to 1600°F. Electric heating elements shall be low watt density with incoloy sheath
and 1˝ screw-in type. Each element shall be controlled by an individually mounted thermostat and high temperature cut-off switch. All internal circuits shall be fused. The outer
jacket shall be of baked enamel finish and shall be provided with full size control compartment for performance of service and maintenance through hinged front panel and shall
enclose the tank with foam insulation. Electrical junction box with heavy duty terminal block shall be provided. The drain valve shall be located in the front for ease of servicing.
Heater tank shall have a three-year limited warranty as outlined in the written warranty. Manufacturer shall supply CSA Certified and ASME Rated T&P Relief Valve.
In keeping with our policy of continuous product improvement, specifications are subject to change without prior notice.
For complete details on CommercialWater HeaterWarranties, contact StateWater Heaters or your State Sales Representative.
For more information on the Sandblaster® contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
SCESS00308
©2008 State Water Heaters
Printed in U.S.A.
|